SOP — Process / Pre-shipment control
Operating procedure applied by Tradvolt before each EVSE (EV charging equipment) container is released from the Chinese load point for shipment to Nigeria, covering seal procurement, sampling inspection per ISO 2859-1, seal application under FIATA documentation rules, and customs filing on the official Nigeria Customs Service portal.
This SOP defines the steps required to audit, apply, and document a high-security bolt seal on FCL containers holding EVSE assemblies and spare parts, when Tradvolt acts as shipper or consolidator on the China (CN) → Nigeria (NG) corridor.
The procedure applies to AC EV chargers, DC fast-charging stations, wallboxes, and associated accessories shipped as commercial cargo; it does not cover break-bulk, project cargo, or air freight shipments.
EVSE units packed into an audited container must satisfy the product-side requirements below; non-eligible units must be reworked before sealing.
The table below defines the 9-step procedure. Owners are explicit; “Input doc” lists what must be on hand at the start of the step, “Output doc” is what that step produces, and “Done-when” is the binary readiness test.
| Step # | Action | Owner | Input doc | Output doc | Done-when |
|---|---|---|---|---|---|
| 1 | Confirm shipping Incoterm and seal responsibility per ICC Incoterms 2020; record seal ownership (shipper, carrier, consolidator). | Trade Ops (Tradvolt) | Sales contract; booking confirmation | Incoterm & responsibility note | Seal ownership is named in the booking note and matches the Incoterm chosen. |
| 2 | Verify supplier seal type: confirm ISO 17712 high-security bolt seal, with manufacturer and batch on file; reject “indicative” or non-marked seals. | Outbound QC | Seal procurement record | Seal lot acceptance record | Seal carton matches recorded manufacturer, batch, and ISO 17712 marking. |
| 3 | Pre-audit container history: verify container number, age, last-cargo declaration, and CSC plate status; record six-side photographs of empty container. | Outbound QC | CSC plate image; container history file | Empty-container photo set (six sides) | All six sides captured at ≥ 1,600 × 1,200 px and stored under the booking ID. |
| 4 | Receive EVSE packing list; cross-check quantity, model, accessories, and serial ranges against the commercial invoice. | Outbound QC + Supplier | Supplier packing list; commercial invoice draft | Packing-list reconciliation sheet | Every line of the packing list maps to a serial range and is reflected on the invoice. |
| 5 | Perform ISO 2859-1 sampling inspection on packed cartons, recording findings at General Inspection Level II, AQL 1.0 (major) / AQL 2.5 (minor) as the working limit; release cartons or trigger rework. | Outbound QC | Inspection checklist; sample plan table | Sampling inspection report | Inspection report is signed and the lot decision (Pass / Rework / Reject) is logged. |
| 6 | Apply high-security bolt seal at the container doors once loading completes; ensure locking pin engages and seal body covers the locking cam. | Outbound QC + Warehouse | Seal acceptance record; loading completion note | Seal application log entry | The bolt seal is hand-tightened, no gap visible between seal body and door cam. |
| 7 | Record the seal number against the container and booking; capture close-up photographs of the seal number and an environment shot showing container + seal. | Outbound QC | Seal application log entry; smartphone/DSLR | Seal-number photo set | Seal number is legible in ≥ 2 photos and matches the seal application log. |
| 8 | Issue the seal audit certificate and bundle with the FIATA-style shipping documents (Bill of Lading, packing list, commercial invoice, certificate of origin, EVSE test summary). | Trade Ops | Seal audit certificate draft; BL draft | Shipment document pack | The document pack is signed and exchanged with the carrier for the Master BL. |
| 9 | File customs entry for Nigeria import clearance using the seal audit certificate within the shipping instruction; verify HS code and duty via the official Nigeria Customs Service portal before filing. | NG Customs Broker | Shipment document pack; Nigeria Customs Service portal filing reference | Nigeria customs entry acknowledgment | Customs entry is accepted on the Nigeria Customs Service portal, with HS code, duty, and seal audit certificate attached. |
The filenames below must appear in the shipment folder before container release. Literal filenames are used internally.
TVT-CNNG-INCTRULE-001.pdf — Incoterm & seal responsibility note (Step 1)TVT-CNNG-SEAL-LOT-002.csv — Seal lot acceptance record (Step 2)TVT-CNNG-CNT-6SIDES-003.zip — Empty-container six-side photo set (Step 3)TVT-CNNG-PKLIST-RECON-004.xlsx — Packing-list reconciliation sheet (Step 4)TVT-CNNG-AQL-INSP-005.pdf — Sampling inspection report (Step 5)TVT-CNNG-SEAL-LOG-006.csv — Seal application log entry (Step 6)TVT-CNNG-SEAL-PHOTOS-007.zip — Seal-number photo set (Step 7)TVT-CNNG-SEAL-AUDIT-CERT-008.pdf — Seal audit certificate (Step 8)TVT-CNNG-DOCPACK-009.zip — Full shipment document pack (Step 8)TVT-CNNG-NG-CUSTOMS-ACK-010.pdf — Nigeria customs entry acknowledgment (Step 9)| Phase | Window | Depends on |
|---|---|---|
| Steps 1–4 (preparation) | Day −3 to Day −1 (calendar days before load) | Booking confirmation; supplier ship-readiness notice |
| Steps 5–7 (inspection + sealing) | Day 0 (load day), 0 → 4 h after load completion | All pallets loaded; container doors ready to close |
| Step 8 (document pack) | Day 0, +1 h after Step 7 | Seal audit certificate signed; carrier BL acknowledged |
| Step 9 (Nigeria customs) | Day −1 to Day +3 (filing window) | Original Bill of Lading; seal audit certificate attached |
Cost slots below are indicative for client reference and remain UNCERTAIN until a quoted booking is issued. Tradvolt does not list hard unit prices in the SOP.
| Slot | Status | Notes |
|---|---|---|
| Bolt seal unit cost | indicative | ISO 17712 high-security bolt seal; price varies with batch size. |
| ISO 2859-1 sampling inspection fee | indicative | Driven by sample plan, lot size, and rework content. |
| Container pre-audit & photo package | indicative | Six-side photo set, CSC plate verification. |
| Nigeria import duties & levies | UNCERTAIN | Determined by HS code, FOB value, and prevailing policy; verify on the Nigeria Customs Service portal at filing time. |
| Origin handling & documentation | indicative | Includes FIATA-style document pack assembly. |
| Item | Value |
|---|---|
| Equipment family | EVSE — Electric Vehicle Supply Equipment (AC chargers, DC fast chargers, wallboxes, accessories) |
| HS code (indicative family) | 8504.40 — Static converters; power supply units for automatic data-processing machines and units thereof. Specific classification within the family must be confirmed against the unit’s nameplate rating, output type, and use at the time of filing. |
| Duty / levy rates | PENDING — lookup at the time of filing on the official Nigeria Customs Service portal; do not hardcode rates in this SOP. |
| Official portal named | Nigeria Customs Service (Nigeria Customs Service portal — for HS code validation, duty computation, and entry filing) |
| Disclaimer | HS codes and duty rates are jurisdiction-specific and change. The HS family and duties listed above are indicative placeholders and must be confirmed against the official Nigeria Customs Service portal for each shipment before an entry is filed. Tradvolt does not warrant a specific classification or rate. |
TVT-CNNG-SEAL-AUDIT-CERT-008.pdf stapled to the Master BL file.TVT-CNNG-SEAL-PHOTOS-007.zip) archived under the booking ID for 7 years.TVT-CNNG-NG-CUSTOMS-ACK-010.pdf) filed with the shipment record.Both links are live. The RFQ route opens the Tradvolt quote form for EVSE CN→NG shipments; the checklist PDF mirrors this page and is printable for warehouse use.
Each factual sentence in this SOP is bound to one of the allow-listed sources below; URLs were retrieved on 2026-09-21.
All other descriptive statements in this SOP (filenames, step counts, owners, format of the document pack) are internal Tradvolt process definitions, not external facts requiring citation.
Disclaimer. This page documents Tradvolt’s internal SOP for the CN→NG corridor. HS codes and duty rates are jurisdiction-specific and may be revised; values shown are placeholders pending lookup on the official Nigeria Customs Service portal at the time of filing. EVSE safety and EMC standards listed are reference standards; the binding list for a specific shipment is defined by the unit’s datasheet and the destination market’s regulations. No specific certificate numbers or transit lead times are committed in this document.